Power Over Ethernet (PoE) Operation for the Series 5300xl Switches
PoE Operating Notes
PoE Operating Notes
Simply disabling a PoE port does not affect power delivery through
that port. To cycle the power on a PD receiving power from a PoE
port on the switch, disable, then re-enable the power to that port. For
example, to cycle the power on a PoE device connected to port 1 on
an xl PoE module installed in slot D:
ProCurve(config)# no interface d1 power
ProCurve(config)# interface d1 power
PoE Event Log Messages
PoE operation generates these Event Log messages. You can also configure
the switch to send these messages to a configured debug destination (terminal
device or SyslogD server).
“Informational” PoE Event-Log Messages
I < MM/DD/YY > < HH:MM:SS > <chassis|ports>:
Message header, with severity, date, system time, and system
module type (chassis or ports). For more information on
Event Log operation, including severity indicators, refer to
“Using the Event Log To Identify Problem Sources” on page C-27.
Slot < slot-id > Ext Power Supply connected, supplying
< actual-power > W of < avail-power > W max.
The switch detected an EPS (External Power Supply) on the
indicated slot and began receiving the wattage indicated by
< actual-power >. The < avail-power > field indicates the maximum
power (wattage) the detected EPS is capable of delivering.
Slot < slot-id > Ext Power Supply disconnected
The indicated slot has lost contact with an external power supply.
11-23