6-16 KP-632 User Manual
Service Menu, Mic Select
This menu item allows the user to select between the Panel and Headset Mic. In the Normal
(defualt) setting, audio from the Panel Mic used. In the Hdst Only, setting audio from the Headset
Mic is used.This is used to force the use of the headset microphone even when the keypanel’s
speaker is being used.
1 Select
Mic Select
from the Service menu, then tap PGM.
2 →
Normal
displays
3 Press ↓↓ to select either
Normal
or
Hdst Only
4 Tap PGM
5 Tap CLR to exit
6 Run Service Menu, Save Cfg, to store Mic Select settings.
Service Menu, Min Volume
This menu item allows the user to set the minimum volume level for both the keypanel speaker
and the headset speaker(s). This is the minimum volume level available on the volume control
located on the front panel of the KP-632.
1 Select
Min Volume
from the Service menu, then tap PGM.
2 →
Speaker
displays
3 Press ↓↓ to select either
Speaker
or
Headset
4 Tap PGM
5 Press ↓↓ or −− to increase or decrease the minimum volume level. The range is -24 dB to
-60 dB or full Mute.
6 Tap PGM
7 Tap CLR to exit
8 Run Service Menu, Save Cfg, to store Min Volume settings.
Service Menu, Mod Assign
Note
Normally, this is a service adjustment that is required only when replacing a key and display
module. It may also be required if for some reason, the key assignments, as displayed in
ADAMedit, appear to be in the wrong positions on the keypanel or expansion panel.
The KP-632 and EKP-632 use module ID numbers (Mod ID numbers) to define the address of
each key and display module. See Figure 6.2. By default, Mod 1 is always assigned to the right
half of the KP-632 and this never changes, since this module has the keypad and is unique.
However, the rest of the modules are identical. When replacing any of these modules, you may
have to reset the Mod ID number as follows:
1 Select
Mod Assign
from the Service menu and tap PGM.
2
Cancel?
displays. To exit the procedure without making changes, tap PGM.
3 All of the alphanumeric displays, except Mod 1, will appear as shown in Figure 6.2. Assign the
Mod IDs as shown in the figure. Repeat the procedure for each module.