4. Connect the RVON-I/O to Ethernet.
5. Set the IP Address for the RVON-I/O (see “Setup IP Addresses” on page 17).
6. Using Telnet or Serial programming, configure the RVON-I/O as follows:
set channel [chan]
dest ip_addr (IP Address of the RVON-1, RVON-8, or RVON-I/O that is connected to the RVON-I/
O)
dest_type (the type of device, either an RVON-1, RVON-8, or RVON-I/O)
dest_chan
dest_codec
set panel [panel]
poll_id (see “Set Panel” on page 32)
NOTE: If the RVON-I/O is in Remote Mode, set the Panel Poll ID to 0, so it will not be seen as
keypanel.
baud
NOTE: To see actual Telnet commands, see “RVON-I/O Command Table” on page 25.
7. Once you are finished configuring the RVON-I/O, type ACTIVATE into the command prompt to activate the
configuration setup on the RVON-I/O
8. To set up the other side of the trunk system, repeat steps 1 through 7.
RVON Serial Pass-through Setup
The Serial Pass through is the path in which data is sent and received.
1. Verify the correct port is selected - on J1 see “Pin Outs for Connections” on page 4.
2. Verify the serial connections are correct.
3. Verify Pass Through Port is enabled (DIP Switch 2 OPEN), see “Connection Diagrams” on page 5.
4. Verify the RVON-I/O baud rate matches the baud rate of the device it is connecting with.
5. Using Telnet or Serial programming, configure the RVON-I/O as follows:
set serial
mode
ip_addr
baud
NOTE: To see actual Telnet commands, see “RVON-I/O Command Table” on page 25.
6. Once you are finished configuring the RVON-I/O, type ACTIVATE into the command prompt to activate the
configuration setup on the RVON-I/O.