Device Connections
22
The intercom port addresses for program input, as well as the low and high ranges for IFB output, are stored in EPROM
memory in the PAP. In some cases, it may be desirable to control program sources and IFB ranges other than those allowed by
the defaults. In such cases, new custom EPROMs can be programmed as needed. Contact your intercom system dealer for
further information.
Connecting a Single PAP
Connect a single PAP to J3 of the Master Controller Breakout Panel as shown in ADAM-101 through ADAM-108
interconnect diagrams on starting on page 35. Use and RS-485 data cable wired as shown in the ADAM-809 installation
drawing on page 53. Connect power to the AC mains connector.
Connecting Additional PAPs
Connect any additional PAPs by wiring them in parallel with the first PAP.
Change the panel number DIP switches in all but one of the PAPs. To do this, remove the covers from the PAP and locate the
8-position DIP switch block on the PMC-15 circuit board. By default, all PAPs are supplied with DIP switches #1 and #2 set
for panel number 1. Reset the switches as shown in Table 6 on page 15, so that each PAP has a unique panel number.
By default, all PAP systems are supplied with the lower of two ranges of IFBs selected. For example, a PAP-952 is set by
default to work with IFB numbers 1 to 24. If a second PAP-952 is connected, it can be reset to work with IFB numbers 25 to
48, if desired.
NOTE: DIP switches 4-8 in PAP systems are not used and their position does not matter.
Programming IFB Defaults to Initialize PAPs
Before a PAP can reassign program inputs, a default configuration for each IFB must first be setup using AZedit. See
“Creating an IFB”.
Note, it is not necessary to have any program sources or output stations connected to setup the IFBs.
Checking PAP Operation
Status of a PAP can be checked by selecting PAP from the Status menu in AZedit.
Alternatively, it is possible to check PAP operation using the XPT (Crosspoint Table) in AZedit. When you select “Force and
Inhibit” from the System menu in AZedit, a port pick list appears. Select one of the IFB output ports. A “Connecting Ports”
table for that port appears. As program sources are reassigned on the PAP front panel, the changes can be viewed in the table
by pressing the ENTER key. As each new program source is connected, a check mark appears next to that port in the table.
TABLE 11. PAP Addresses
Model
Default Ports for
Program Input
Panel No.
(Default = 1)
IFB Range
Low (Default) High
PAP-940 1-24 1-4 1-40 41-80
PAP-950-50 1-50 1-4 1-50 51-100
PAP-951 1-8 1-4 1-12 13-24
PAP-952 1-16 1-4 1-24 25-48