Seitenansicht 16
15
KP-32 Addressing
KP-32 Addressing
A rotary switch is used to indicate the logical port address the keypanel is to use when communicating with the
Matrix. The switch is read continuously through polling by the matrix. If the port address is changed, the new
address is effective immediately.
NOTE: The address pot, by default is shipped with an invalid address to ensure that there are no conflicts with
existing keypanels. It is important to set the address port for the KP-32 keypanel for it to function properly.
The Address switch has a white pointer - pointed at 7. This indicates port 7 or the given AIO card. Determine the proper
setting using Table 6.
TABLE 6. Program Assign Panel DIP Switch Settings for Panel Number
ID SW1 SW2 SW3 SW4
0 Open Open Open Open
1 Close Open Open Open
2 Open Close Open Open
3 Close Close Open Open
4OpenOpenCloseOpen
5 Close Open Close Open
6 Open Close Close Open
7 Close Close Close Open
8 Open Open Open Close
9 Close Open Open Close
10 Open Close Open Close
11 Close Close Open Close
12 Open Open Close Close
13 Close Open Close Close
14 Open Close Close Close
15 Close Close Close Close
TABLE 7. UIO-256 DIP Switch Settings for Input/Output Range
I/O
Range
DIP Switch Settings
1 2 3 4 5 6 7 8
1-16
a
a. Default
Open Closed Open Open Open Open Open Closed
17-32 Open Closed Open Closed Open Open Open Closed
33-48 Open Closed Open Open Closed Open Open Closed
49-64 Open Closed Open Closed Closed Open Open Closed
Seitenansicht 16