13
WARNING: DIP Switches 1, 6, and 8 should always be left in the OPEN position. These are reserved for debugging and can have unintended consequences if not left in the
OPEN position.
TABLE 2. MCII-e Factory set DIP Switch Settings
DIP Switch 1 Debug Only! Must be in OPEN position.
DIP Switch 2
Sets the baud rate for AZedit serial connection via J1.
By default, AZedit is set for COM1 and 38,400 kbps (38.4k). The baud rate set in AZedit must
match the baud rate setting of the Master Controllers in ADAM.
Default: OPEN
OPEN: 9600 baud
CLOSED: 38.4k baud
DIP Switch 3, 4, and 5 Reserved, keep in OPEN position.
DIP Switch 6 Debug Only! Must be in OPEN position.
DIP Switch 7
Determines the Master / Slave Frame in a multi-frame system
Default: CLOSED
OPEN: Slave Frame
CLOSED: Master Frame
DIP Switch 8 Debug Only! Must be in OPEN position.
TABLE 3. Relationship between Audio Input/Output Cards, Intercom Ports, and Logical Keypanel Numbers
Logical
Keypanel
Number
Intercom Port Numbers, Grouped by Audio I/O Card Numbers
AIO
1
AIO
2
AIO
3
AIO
4
AIO
5
AIO
6
AIO
7
AIO
8
AIO
9
AIO
10
AIO
11
AIO
12
AIO
13
AIO
14
AIO
15
AIO
16
AIO
17
1 1 9 1725334149576573818997105113121129
2 2 10 18 26 34 42 50 58 66 74 82 90 98 106 114 122 130
3 3 11 19 27 35 43 51 59 67 75 83 91 99 107 115 123 131
4 4 12 20 28 36 44 52 60 68 76 84 92 100 108 116 124 132
5 5 13 21 29 37 45 53 61 69 77 85 93 101 109 117 125 133
6 6 14 22 30 38 46 54 62 70 78 86 94 102 110 118 126 134
7 7 15 23 31 39 47 55 63 71 79 87 95 103 111 119 127 135
8 8 16 24 32 40 48 56 64 72 80 88 96 104 112 120 128 136
NOTE: For AIO-16 cards, see the AIO-16 User Manual (p/n 9350-7726-000).