The user must install only the kits listed below. Combinations of
extension coaxial cables and antennas that result in a radiated
power level exceeding 100mW EiRP are illegal in the
European Union.
The user will find more information on these kits in Section 11,
“Accessories and Replacement Parts”.
China Compliance Information
The China version and European version of the BTR-240 are the
same product. This BTR-240 has a typical output power of the
50mW. The EiRP (Effective isotropic Radiated Power) limit for
China is 100mW. The standard, 3dB gain, omni-pattern antennas
shipped with the European/China version of the BTR-240,
combined with its output power, are under this limit. However,
some applications may require the installation of remote antennas
by the use of extension coaxial cables. For this purpose the China
version of the BTR-240 has been approved for use with kits in
Table 13-1. The kits contain an antenna, coaxial cable(s) of a
length to make the EiRP compliant with the European Union and
Chinese regulations, and an adapter for coupling the antenna /
antenna pigtail to the coaxial cable.
Combinations of extension coaxial cables and antennas that
result in a radiated power level exceeding 100mW EiRP are
illegal in China.
Antenna Kit
Description
BTR-240
(European/China)
Output, dBm
Cable
Loss, dB
Antenna
Gain, dB
Maximum
Transmitted
Power, dBm
RA-5E
5dBi gain, omni, magnetic mount
antenna with 1.2m (4 ft) pigtail and an
additional 1.5m (5 ft) of coaxial cable
and an adapter.
+17
(50mW)
2.4 5 +19.6
(91mW EiRP)
RA-7E
7dBi gain, omni, with AB-24 antenna
mounting bracket and 4.6m (15ft) of
coaxial cable.
+17
(50mW)
4.2 7
+19.8
(96mW EiRP)
FP-11E
11dBi gain, directional, flat panel
antenna with 7.6m (25ft) of coaxial cable
and and adapter.
+17
(50mW)
8.2 11 +19.8
(96mW EiRP)
ANT-FBE
11dBi dual flat panel antenna with dual
pieces of 7.6m (25ft) coaxial cable and
two adapters.
+17
(50mW)
8.2 11 +19.8
(96mW EiRP)
Table 13-1
Approved antenna kits for use in the European Union and China that ensure an EiRP of 100mW or less.
13-3
Kommentare zu diesen Handbüchern