INSTALLATION
OPTION DIP SWITCH SETTINGS
Switch 1: Latch Enable/Disable
Default setting = Open: Enable.
Description: An intercom key can always be turned on for momentary conversation by pressing and
holding the key during the conversation. There is also an electronic latching feature that lets you tap
intercom keys to turn them on or off. This permits convenient hands-free conversation. However it can also
result in a talk circuit being left on unintentionally. For example, a key that talks to a public address system
could be accidentally left on. Or an IFB key (a type of key assignment that is often used by a director or
producer to give instructions to a listener, such as a news anchor during a television broadcast) could
accidentally be left on, causing confusion for the IFB listener. To prevent such accidents, the latching
feature can be turned off.
DIP switch 1 disables latching for the entire keypanel. If you just need to disable latching for selected
keys, leave DIP switch 1 in the "Open" position. Then, disable latching for the desired keys using the
"D" check boxes in the Keypanels / Ports setup screen of ADAMedit.
Switch 2: Key Gain Enable / Disable
Default setting = Open: Enable.
Description: Enables or disables the Key Gain item in the Key Assign menu.
"Key Assign Menu, Key Gain", page 33.
Switch 3: Screen Saver Enable / Disable
Default setting = Open: Enable.
With Screen Saver enabled, the KP-32 will shut off the display and enter a low-power state after a few
minutes of inactivity. The display reactivates instantaneously on incoming call or when the keypanel
operator actuates any control. As with all fluorescent and back-lit LCD displays, some dimming will occur
after many years of operation. Using the screen saver helps maximize the display life.
Switch 4: Call Flash Timeout
Default setting = Open: 15 Second Flash.
Description: Whenever there is an incoming call and there is a talk key assigned to the caller, the talk LED
next to that key will flash. The flash can be set for 15 second timeout, or until the caller's talk key is
released.
Switch 5: Footswitch Enable / Disable
Default = Open: Disabled.
Description: The optional Connector Module has a footswitch (GRP CALL) input. If the footswitch is
enabled (DIP switch 5 set to the "Closed" position), then keys that are latched on will not activate until the
footswitch is closed. Latched keys are indicated by winking green talk LEDs (on time less than off time),
and when the footswitch is activated, the LEDs provide the normal talk-on indication.
See Also, "LED Indications for Intercom Keys", page 13.