RTS CM300 Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen für Türsprechanlagen RTS CM300 herunter. RTS CM300 Specifications Benutzerhandbuch

RTS 2nd Generation SERVO AMPLIFIER
1
PVD 3487 GB 03/2004

CONTENTS

SAFETY INSTRUCTIONS
……………………………………………………………………………3
1.

GENERAL

5
2.

TECHNICAL SPECIFICATIONS

6
2.1
RTS Servo amplifier performance chart
7
2.2
Block diagram
8
3.

DIMENSIONS, LABELLING,

9
3.1
Dimensions
9
3.2
Labelling
23
4.

- ELECTRICAL CONNECTIONS

24
4.1
General Wiring Requirements
24
4.1.1
Appliance handling
24
4.1.2
Electromagnetic compatibility
24
4.2
RTS Servo amplifier connection
25
4.3
Front Panel
30
4.4
Terminal blocks X1, X2 AND X3
35
4.5
Terminal block X2 connection
38
4.6
Terminal block X3 connection
38
4.7
Accessories
39
4.7.1
Plug-in Customisation card
39
4.7.2
Extra choke
39
4.7.3
Transformer
40
4.7.4
Mains filter
40
5.

LED DISPLAYS

49
6.

SERVO AMPLIFIER ADAPTATION

50
7.

COMMISSIONING

51

PDF-Datei · ·

Drucken

Dokument drucken

Teilen

Inhaltsverzeichnis

Seite 1 - CONTENTS

CONTENTS SAFETY INSTRUCTIONS 3 1. GENERAL 5 2. TECHNICAL SPECIFICATIONS 6 2.1 RTS Servo amplifier performance chart 7 2.2 Block diagram 8 3.…

Seite 2

1 Speed loop rapid adjustment 52 7.2 Complete speed loop adjustment 53 7.3 Diagnostic helpI 55 7.4 Calibration 56 7.4.1 Tachometric generator voltage…

Seite 3

SAFETY Servodrives present two main types of hazard : - Electrical hazard Servoamplifiers may contain non-insulated live AC or DC components. Users…

Seite 4 - • Connectors

Upon delivery All servoamplifiers are thoroughly inspected during manufacture and tested at length for bugs before shipment. Unpack the servoamplifier…

Seite 5 - 1. GENERAL

GENERAL The RTS servo amplifier is designed for four-quadrant control of DC servo motors up to mechanical powers of 2500 W. It incorporates power and…

Seite 6 - 2. TECHNICAL SPECIFICATIONS

- COMPLIANCE WITH STANDARDS RTS bears the CE mark under European Directive 89/336/EEC as amended by Directive 93/68/EEC on electromagnetic…

Seite 7

1 RTS Servo amplifier performance chart RTS CHARACTERISTICS at 40°C ambient temperature 3/10-40M single-phase 10/20-60 single/three- phase 12/24---B…

Seite 9 - 3. DIMENSIONS, LABELLING

DIMENSIONS, LABELLING, 3.1 Dimensions RTS servo amplifiers are available in two formats for vertical mounting : - in single Europe 3U DIN rack, in two…

Seite 10

RTS PARVEX Ref. Input supply Ventilation Supply Dimensional drawing (with or without customisation card) W RTS 3/10-40M RTS 5104-301 Single-phase Not…

Seite 11

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 12

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 13

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 14

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 15

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 16

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 17

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 18

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 19

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 20

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 21

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 22

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 23 - 3.2 Labelling

2 Labelling RTS SERVO AMPLIFIER IDENTIFICATION Each RTS servo amplifier has an identification label affixed either on the metal plate at the rear for…

Seite 24 - 4. - ELECTRICAL CONNECTIONS

- ELECTRICAL CONNECTIONS 4.1 General Wiring Requirements 4.1.1 Appliance handling See the safety instructions given at the beginning of this manual.…

Seite 25

MAINS FILTERING The mains filter must be mounted as close as possible to the potential reference plate between the mains and the power supply (p.46…

Seite 26

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 27

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 28

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 29

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 30 - 4.3 Front Panel

3 Front Panel RTS V2 Battery (Rack) RTS V2 Battery (wall-mounted)

Alle 65 Seiten anzeigen
Seite 31

RTS V2 10 E (Rack) RTS V2 12 E (Rack)

Seite 32

RTS V2 12 E (wall-mounted) RTS V2 12 A / 130V (wall-mounted) 1PH and 3PH

Seite 33

RTS V2 16 A / 190 V (wall-mounted)

Seite 34

RTS V2 20 A / 130 V (wall-mounted)

Seite 35

4 Terminal blocks X1, X2 AND X3 Torque value : terminal block X1, 0.4 Nm terminal blocks X2 and X3, 0.8 Nm. Terminal block X1 front panel connection…

Seite 36

DESCRIPTION N° NAME TERMINAL BLOCK X1 7 8 9 10 I RED % I max R(K ) 0 VA SPEED OR I OUT SPEED EN. I - O I A nalogue reduction of current. Reduction may…

Seite 37

DESCRIPTION N° NAME TERMINAL BLOCK X1 11 12 13 14 TORQUE EN. RESET I I - - To be connected via an external contact to terminal 13 to enable current…

Seite 38

5 Terminal block X2 connection Recommended cable cross-section : 0.5 - 1.5 mm² DESCRIPTION N° NAME TERMINAL BLOCK X2 1 2 3 4 5 +15 V 0V -15V READY…

Seite 39 - 4.7 Accessories

7 Accessories 4.7.1 Plug-in Customisation card The RTS includes a number of components for customising the axis. These components are mounted as…

Seite 40 - 4.7.4 Mains filter

Recommended combinations : RTS 3/10-40M single-phase RTS 10/20-60 single-phase SF020231 12A-2x0.25 mH or three-phase drawing FELX 303434 (p.42). RTS…

Seite 41

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 42

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 43

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 44

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 45

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 46

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 47

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 48

RTS 2nd Generation SERVO AMPLIFIER PVD 3487 GB 03/2004

Seite 49 - 5. LED DISPLAYS

LED DISPLAYS LED displays are possible only if the supply voltage is present. The "Ready" relay, in this case, must not be incorporated in the…

Seite 50

SERVO AMPLIFIER ADAPTATION Selector switch positions * Selector S1 * Position Speed control. Speed feedback is used. Usual case. * Position Current…

Seite 51 - 7. COMMISSIONING

COMMISSIONING - Check the connection of the following items : - transformer - relay system, especially the emergency stop - motor and any smoothing…

Seite 52 - Terminal block X2

1 Speed loop rapid adjustment * Offset adjustment Once ambient temperature is stabilised, adjust zero speed to the mid-position with the "SPEED…

Seite 53

2 Complete speed loop adjustment Systematically applicable when J charge 10 J motors Caution As servo amplifiers are factory set based on…

Seite 54

FIG 2 In some cases, gain limitation is due to resonance: the motor starts to whistle or vibrate at high frequencies (> 100 Hz). A -1 filter must be…

Seite 55 - 7.3 Diagnostic helpI

3 Diagnostic helpI ENERGISING Check : • terminals X1/10 and X1/11 must be connected to 0V • selector S1 must be in correct position • reference…

Seite 56 - 7.4 Calibration

4 Calibration The components below are stud mounted and used to calibrate the servo amplifier for the corresponding motor. Calibration is done at the…

Seite 57

TACHOMETER SYSTEM EMF RATED SPEED

Seite 58 - TACHO selection

Symbols used Nn = rated speed of application for 10 V reference speed lim = maximum pulse current of motor max = maximum pulse current of servo…

Seite 59 - Fine speed adjustment

4.2 Rated speed selection (R105) Resistor R105 calibrates the useful speed of the application. For a speed reference of ± 10 V, the speed…

Seite 60 - (terminal block X1)

4.3 Pulse current adjustment (R113) R113 modifies the maximum current authorised by the servo amplifier. The standard pulse current is twice the value…

Seite 61

4.5 Time constant adjustment I = f(t) (R109) The system time constant is factory set so the servo amplifier accepts maximum current for one second…

Seite 62

4.7 Adjustment of current limitation curve versus speed I F(n) (R131 - 132) Resistor R131 is used to select the zero current point on the speed…

Seite 63

R132 values % of maximum current Ns - Nr 20 40 60 80 100 500 1000 1500 2000 2500 3000 3500 4000 27.4 k 12.1 k 8.25 k 6.81 k 5.62 k 4.75 k 3.32 k 47.5…

Seite 64

To calculate motor speed, coefficients R and KE must be calibrated by the resistor values below : R 133 [k ] R 134 [k ] RTS 3/10 - 40 RTS 10/20 - 60…

Seite 65

4.11 dc voltage calibration (RB) Resistor RB is used to adapt limit values: MAX U, MIN U, tripping of supply voltage recovery. The standard values are…

Weitere Dokumente für Türsprechanlagen RTS CM300

Fragen zu RTS CM300

Zu diesem Handbuch gibt es noch keine Fragen. Stellen Sie die erste.

Frage stellen

Wir antworten aus dem Handbuch und nennen die Seite. Die Frage erscheint nach der Prüfung auf der Website.

Alle Fragen und Antworten ›

Verwandte Produkte und Handbücher für Türsprechanlagen RTS CM300